Floor heating cable TCPR Wooden floors
Part.no Ω/m Length m Surface m² Power W Voltage V 8987300 12,00 27 2 165 230 8987301 8,00 27 3 245 230 8987302 5,35 31 4 320 230 8987303 4,00 34 5 390 230 8987304 2,90 40 6 455 230 8987305 1,90 50 7 555 230 8987306 1,30 64 8 635 230 8987307 1,00 74 9 720 230 8987308 0,82 81 10 800 230 8987309 0,65 93 11 875 230 8987310 0,65 85 12 960 230 8987311 0,45 113 13 1040 230 8987312 0,45 105 14 1120 230 8987313 0,36 122 15 1200 230 8987314 0,36 116 16 1270 230 8987315 0,25 155 17 1360 230 8987316 0,25 147 18 1440 230 8987317 0,25 139 19 1520 230 8987318 0,25 135 20 1570 230 THE KIT CONTAINS: Heating cable according to the table with cold-lead-in cable mounted, caution signs.
Technical DataTechnical data
Cable data
Electric field strength not measurable cable < 3 V/m
Magnetic field strength not measurable cable < 0.06 micro TesslaBasic type 90 CM according to IEC800 Approved, tested by SEMKO (Sweden) • SETI (Finnland) • NEMKO (Norway) Meet requirements from: VDE (Germany) • BS (England) • DEMKO (Denmark) Rated voltage 440 V Sheath temperature (Tm) max +90°C Process temperature
– Cable off(Tp)
(TpOff) max +90°CInstallation temperature min -10°C Bending radius min 25 mm Dimension 5.5 ± 0.5 mm Weight 92 kg/1000m Floorheating cable TCPR Thin floors
Part.no Ω/m Length m Surface m² Power W Voltage V 8987332 12,00 20 2 220 230 8987333 8,00 23 3 290 230 8987334 4,00 33 4 400 230 8987335 2,90 38 5 480 230 8987336 1,90 46 6 605 230 8987337 1,30 57 7 715 230 8987338 1,00 65 8 815 230 8987339 0,82 70 9 920 230 8987340 0.65 78 10 1045 230 8987342 0,45 95 11-12 1235 230 8987344 0,36 107 13-14 1375 230 8987346 0,25 130 15-16 1630 230 8987348 0,18 158 17-18 1860 230 8987350 0,18 150 19-22 1960 230 THE KIT CONTAINS: Heating cable according to the table with cold-lead-in cable mounted, caution signs.
Technical DataTechnical data
Cable data
Electric field strength not measurable cable < 3 V/m
Magnetic field strength not measurable cable < 0.06 micro TesslaBasic type 90 CM according to IEC800 Approved, tested by SEMKO (Sweden) • SETI (Finnland) • NEMKO (Norway) Meet requirements from: VDE (Germany) • BS (England) • DEMKO (Denmark) Rated voltage 440 V Sheath temperature (Tm) max +90°C Process temperature
– Cable off(Tp)
(TpOff) max +90°CInstallation temperature min -10°C Bending radius min 25 mm Dimension 5.5 ± 0.5 mm Weight 92 kg/1000m Floorheating cable TCPR Concrete floor 30-50mm
Part.no Ω/m Length m Surface m² Power W Voltage V 8987183 12,00 15 2 284 230 8987184 8,00 17 3,5-4 390 230 8987185 5,35 20 4,5-5 495 230 8987186 4,00 23 5-6 575 230 8987187 2,90 27 6-7 679 230 8987188 1,90 35 8-9 795 230 8987189 1,30 45 9-10 905 230 8987190 1,00 53 10-11 1000 230 8987192 0,65 63 12-13 1290 230 8987196 0,45 73 14-16 1610 230 8987198 0,36 82 17-18 1790 230 8987202 0,25 100 19-21 2115 230 THE KIT CONTAINS: Heating cable according to the table with cold-lead-in cable mounted, caution signs.
Technical DataTechnical data
Read more under the category Data Sheets.