Safe-T

VELOX SAFE-T, SELF-LIMITING CABLE
safet-nummer
  1. Sheath of Teflon (CT)
  2. Armouring 1.5mm²
  3. Armouring layer of thermoplastic rubber (CR)
  4. Semiconductive material with self-limiting characteristics (the resistance inreases with rising temperature)
  5. Conductor

Area of use

Roof applications.

Cble data

Basic type 65 CM acc.to SS 424 24 11
Tested and approved by SEMKO (Sweden) • SETI (Finnland) • UL (USA) • Det norske Veritas • Bureau Veritas
Rated voltage: 220 – 240 V
Output W/m -10°C in air ≈ 22 W/m
0°C in air ≈ 19 W/m
+65°C in air ≈ 2 W/m
0°C in ice/water ≈ 36 W/m
Maximum cable length for max. 20% power loss 58 meter
Installation temperature min -20°C
Bending radius min 25 mm
Dimension: 11.1 x 5.0 mm
Weight: 118 kg/1000m
Part.no 89 861 45

Max. cable length based on fuse and start-up temperature. Supply voltage 230/240V

Table 1

Fusing Cable length/Start-up temperature
-20°C 0°C +10°C
10 A 30 m 40 m 50 m
16 A 48 m 64 m 78 m
20 A 60 m 80 m 97 m