Glass woven tape
Glass woven tape 50mm x 12mm
Area of use
Mounting and fixing of heating cables and heating foils.
Characteristics
Provides good lasting fixation of for example heat tracing wrapped around pipe, will not shrink, stretch or burn and has a high tensile strength.
Base: | Glass woven tape |
Adhesive substance: | Acrylic |
Thickness: | 0,17 mm |
Colour: | White |
Adhesion to steel: | 0.44kg/cm |
Tensile strength: | 26kg/cm |
Max. stretching | 5% |
Protective backing | None |
Temperature range | -30°C / 140°C |
Part.no: | E89 992 51 |
Connection/End termination BTL
Connection-/End termination kit BTL
Part No: 8986139
A | Thread PG 11 | 1 pc |
B | Shrinking tube yellow/green | 80mm |
C | Shrinking tube 3 mm 80mm | 2 st |
D | Shrinking tube 9,4 mm | 25mm |
E | Shrinking tube 9,4mm | 90mm |
F | Shrinking tube 6mm | 30mm |
G | Caution sign PIPE | 1 st |
Supplementary kit (internal) BTL incl. R20-thread
Part.no: 8986138
Aluminium tape
Aluminium tape 90°C 50x50mm
Area of use
Mounting and fixing of heating cables and heating foils.
Characteristics
Provides good dissipation of heat and a substantial increase in power output if applied to self-limiting heating cable covering it completely. Protects a conventional heating cable against local overheating caused by penetration into insulation material.
Part.no: | E89 992 44 |
Base: | Woven glass-cloth reinforced aluminium foil |
Adhesive substance: | Acrylic |
Thickness: | 0,105mm |
Colour: | Blank Aluminium |
Adhesion to steel: | 1850gr/25mm |
Tensile strength: | 10.8Kp/25mm |
Diffusion density: | below 1g/m²/24 tim |
Max stretching: | 5% |
Protective backing: | Silicone treated paper |
Temperature range: | -5°C / 90°C |
Should be stored in a dry, dark space with an indoor air humidity of 50% and a temperature of +15°C to 20°C. |
R20 Thread
R20-thread – BTL
Part.no: 8989195
Thread for internal installations.
Caution Sign/tape
Caution Sign Ground
Part.no: 8999246
Area of use
Caution labels should be mounted on a visible location for the application and at the central.
For piping marks should be made each 3 meter.
Material: | Plastic |
Length: | 145 mm |
Width: | 103 mm |
Part.no | 89 992 46 Ground 89 992 47 Pipes 89 992 48 Roof |
Caution tape for pipes
Length: | 32 mm |
Width: | 75 mm |
Part.no: | 89 992 49 |
ELCB
DRNL-7-63 ELCB
Area of use
The DRNL-7-63 complies with IEC 61008. It can cut off the faulty circuit immediately on the occasion of shock hazard or earth leakage. It is applied in varieties of plants, enterprises, buildings, constructions, commercial hotels or homes, in circuits up to single phase 230V, tree-phase 400V 50 or 60 Hz.
Technical data
Standard: | IEC61008 |
Tripping time (instaneous): | Typ G 10ms delay; Typ S 40ms delay with selection |
Rated Voltage: | (UC): 230V/400V;50/60Hz |
Rated current: | (In) 25A |
Rated tripping current: | 30,100,300,500mA |
Rated non-tripping current: | 0.5In |
Sensitivity: | Type A and type AC |
Rated short circuit strength (Inc): | 6000A |
Back-up fuse short circuit: | In=25-63,63A gL In=80A 80A gL |
Rated faulty breaking capacity Im | In=500A |
Electrical life: | > 4000 times |
Mechanical life: | > 20000 times |